Conduit Properties

The physical properties of all conduits after developing the 2D model are listed in the following table.

Name

Inlet Node

Outlet Node

Description

Cross Section Type

Maximum Depth

Active

C176

J1243

J1270

Open Channel

IRREGULAR

13.45

FALSE

C187

J1254

J1270

Storm MainLine

CIRCULAR

1

TRUE

C189

J1270

J1256

Storm MainLine

CIRCULAR

1.25

TRUE

C207

J1269

J1280

Storm MainLine

CIRCULAR

1

TRUE

C215

J1467

J1277

Storm MainLine

CIRCULAR

1.25

TRUE

C217

J1279

J1459

Storm MainLine

CIRCULAR

1

TRUE

C218

J1462

J1280

Storm MainLine

CIRCULAR

1.5

TRUE

C219

J1292

J1277

Storm MainLine

CIRCULAR

1

TRUE

C223

J1284

J1459

Storm MainLine

CIRCULAR

1

TRUE

C227

J1277

J1288

Storm MainLine

CIRCULAR

1.25

TRUE

C231

J1298

J1288

Storm MainLine

CIRCULAR

1

TRUE

C238

J1288

J1309

Open Channel

IRREGULAR

19.12

FALSE

C239

J1299

J1937

Storm MainLine

CIRCULAR

1

TRUE

C248

J1405

J1308

Open Channel

IRREGULAR

23.52

FALSE

C249

J1309

J1308

Open Channel

IRREGULAR

9.77

FALSE

C265

J1308

J1472

Storm MainLine

CIRCULAR

2

TRUE

C266

J1324

J1323

Storm MainLine

CIRCULAR

1

TRUE

C275

J1323

J1473

Storm MainLine

CIRCULAR

1.5

TRUE

C401

J1459

J1281

Storm MainLine

CIRCULAR

1

TRUE

C402

J1281

J1460

Storm MainLine

CIRCULAR

1.5

TRUE

C403

J1460

J1461

Storm NetworkLine

CIRCULAR

1.5

TRUE

C404

J1461

J1462

Storm MainLine

CIRCULAR

1

TRUE

C405

J1280

J1463

Storm MainLine

CIRCULAR

1.5

TRUE

C406

J1463

J1464

Storm NetworkLine

CIRCULAR

1

TRUE

C407

J1465

J1256

Storm MainLine

CIRCULAR

1.25

TRUE

C408

J1464

J1465

Storm MainLine

CIRCULAR

1.25

TRUE

C409

J1256

J1466

Storm MainLine

CIRCULAR

1.5

TRUE

C410

J1466

J1467

Storm MainLine

CIRCULAR

2.5

TRUE

C411

J1937

J1309

Storm NetworkLine

CIRCULAR

1

TRUE

C465

J1472

J1323

Storm MainLine

CIRCULAR

1.5

TRUE

C466

J1473

OF1

Storm MainLine

CIRCULAR

1.5

TRUE

NB:

  • Maximum Depth represents the vertical distance from the invert to the top width level in the cross-section for an irregular channel. For a circular pipe, it is the internal diameter.
  • Inlet and outlet offsets of the conduits are set to zero e.g. conduit bottoms coincide with the invert of inlet and outlet nodes.
  • Length of the conduits used in this model is 2D e.g. elevation differences in inlet and outlet nodes are not considered in length computation. 
  • Active status interprets which conduits will be considered for calculation as well as written in the INP.


Note that no minor loss, storage and transport are considered in the conveyance network to keep the analysis simple.